Recall ID # 97V144000 - FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
| Recall Date: |
SEP 03, 1997 |
| Component: |
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY |
| Model Affected: |
TRACER |
| Potential Units Affected: |
64000
Recall Details
|
Recall Date:
SEP 03, 1997
Model Affected:
1995 MERCURY TRACER
Summary:
VEHICLE DESCRIPTION: PASSENGER VEHICLES EQUIPPED WITH 1.9L ENGINES, BUILT AT THE HERMOSILLO OR WAYNE ASSEMBLY PLANTS AND ORIGINALLY SOLD OR CURRENTLY REGISTERED IN NEVADA, FLORIDA, HAWAII, TEXAS, CALIFORNIA, LOUISIANA, GEORGIA, SOUTH CAROLINA, MISSISSIPPI, OKLAHOMA, ALABAMA AND ARKANSAS. CRACKS CAN DEVELOP IN THE FUEL TANK NEAR THE HEAT SHIELD ATTACHMENT RESULTING IN FUEL LEAKAGE IF THE CRACKS GO THROUGH THE FUEL TANK WALL.
Consequence:
FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE CAN RESULT IN A VEHICLE FIRE.
Remedy:
DEALERS WILL REMOVE THE HEAT SHIELD ATTACHMENTS. THIS WILL NOT AFFECT HEAT SHIELD LOCATION OR FUNCTION, AS THE ATTACHMENTS ARE INTENDED TO KEEP THE SHIELD IN PLACE UNTIL THE FUEL TANK IS INSTALLED IN THE VEHICLE. AFTER INSTALLATION, THE FUEL TANK STRAPS RETAIN THE HEAT SHIELD.
Potential Units Affected:
64000
Notes:
FORD MOTOR COMPANY 97S79

Recall ID # 97V145000 - FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
| Recall Date: |
SEP 03, 1997 |
| Component: |
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY |
| Model Affected: |
TRACER |
| Potential Units Affected: |
600
Recall Details
|
Recall Date:
SEP 03, 1997
Model Affected:
1995 MERCURY TRACER
Summary:
VEHICLE DESCRIPTION: PASSENGER VEHICLES EQUIPPED WITH 1.9L ENGINES, BUILT AT THE HERMOSILLO ASSEMBLY PLANT AND ORIGINALLY SOLD OR CURRENTLY REGISTERED IN ARIZONA. CRACKS CAN DEVELOP IN THE FUEL TANK NEAR THE HEAT SHIELD ATTACHMENT RESULTING IN FUEL LEAKAGE IF THE CRACKS GO THROUGH THE FUEL TANK WALL.
Consequence:
FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE CAN RESULT IN A VEHICLE FIRE.
Remedy:
DEALERS WILL REMOVE THE HEAT SHIELD ATTACHMENTS. THIS WILL NOT AFFECT HEAT SHIELD LOCATION OR FUNCTION, AS THE ATTACHMENTS ARE INTENDED TO KEEP THE SHIELD IN PLACE UNTIL THE FUEL TANK IS INSTALLED IN THE VEHICLE. AFTER INSTALLATION, THE FUEL TANK STRAPS RETAIN THE HEAT SHIELD.
Potential Units Affected:
600
Notes:
FORD MOTOR COMPANY 97S80

Recall ID # 94V218000 - AIR BAGS:FRONTAL
| Recall Date: |
NOV 10, 1994 |
| Component: |
AIR BAGS:FRONTAL |
| Model Affected: |
TRACER |
| Potential Units Affected: |
240
Recall Details
|
Recall Date:
NOV 10, 1994
Model Affected:
1995 MERCURY TRACER
Summary:
THE DRIVER SIDE AIR BAG MODULE CAN HAVE AN INADEQUATELY WELDED INFLATOR CANISTER.
Consequence:
IN THE EVENT OF A COLLISION, THE WELD SEAM CAN SEPARATE, CAUSING THE AIR BAG TO FAIL TO DEPLOY PROPERLY AND HOT GASES TO BE EXPELLED FROM THE BACK OF THE STEERING WHEEL. THIS CAN RESULT IN AN INCREASED RISK OF PERSONAL INJURY FROM THE HOT GASES AND THE AIR BAG FAILURE.
Remedy:
DEALERS WILL INSTALL A NEW AIR BAG MODULE.
Potential Units Affected:
240
Notes:
FORD MOTOR COMPANY