'87 Pontiac Bonneville Recalls
| Recall Date: |
JUL 10, 1987 |
| Component: |
ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS |
| Model Affected: |
BONNEVILLE |
| Potential Units Affected: |
5162
Recall Details
|
Recall Date:
JUL 10, 1987
Model Affected:
1987 PONTIAC BONNEVILLE
Summary:
THE HEADLAMP CIRCUIT BREAKER MAY OVERHEAT AT LOW BEAM CAUSING AN INTERMITTENT HEADLAMP CIRCUIT.
Consequence:
HEADLAMP AND FOGLAMPS WOULD GO OUT SUDDENLY REDUCINGDRIVER VISIBILITY, WHICH COULD RESULT IN A VEHICLE CRASH.
Remedy:
REVISE FOGLAMP CIRCUIT TO PREVENT OVERHEATING OF HEADLAMP CIRCUIT.
Potential Units Affected:
5162
Notes:
GENERAL MOTORS CORP.
| Recall Date: |
SEP 01, 1987 |
| Component: |
ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS |
| Model Affected: |
BONNEVILLE |
| Potential Units Affected: |
479715
Recall Details
|
Recall Date:
SEP 01, 1987
Model Affected:
1987 PONTIAC BONNEVILLE
Summary:
AN IN LINE FUSIBLE LINK MAY MELT DOWN AND CAUSE A FIRE.
Consequence:
THE IN LINE FUSIBLE LINK LOCATED IN THE AREA OF THEPLASTIC WINDSHIELD WASHER BOTTLE BRACKET MAY, UNDER A HIGH RESISTANCE LOAD,MELT DOWN AND IGNITE THE WASHER BOTTLE BRACKET RESULTING IN AN ENGINECOMPARTMENT FIRE.
Remedy:
THE WINDSHIELD WASHER BOTTLE BRACKET WILL BE REPLACED.
Potential Units Affected:
479715
Notes:
GENERAL MOTORS CORP.
| Recall Date: |
MAY 19, 2006 |
| Component: |
FUEL SYSTEM, GASOLINE |
| Model Affected: |
BONNEVILLE |
| Potential Units Affected: |
88303
Recall Details
|
Recall Date:
MAY 19, 2006
Model Affected:
1987 PONTIAC BONNEVILLE
Summary:
CERTAIN REPLACEMENT FUEL FILTERS, FRAM BRAND NAME P/N G3727, WITH DATE CODES X52911 THROUGH X60801 SEQUENTIALLY OR X600141 AND A MEXICO COUNTRY OR ORIGIN MARKING ON THE FUEL FILTER HOUSING MANUFACTURED FROM OCTOBER 18, 2005, THROUGH MARCH 21, 2006, SOLD FOR USE ON THE VEHICLES LISTED ABOVE AND ON CERTAIN SCHOOL BUSES. (TO SEE THE SCHOOL BUS ENGINE SIZES, CLICK ON "DOCUMENT SEARCH" AND THEN "BUS APPLICATIONS"). THE CONNECTOR ON THE FUEL FILTER WAS NOT MANUFACTURED TO HONEYWELL'S SPECIFICATION. AS A RESULT, THE O-RING MAY NOT SEAT CORRECTLY ON THE FUEL LINE.
Consequence:
THIS CONDITION MAY CAUSE AN INADEQUATE SEAL AT THE CONNECTION, POTENTIALLY LEADING TO A FUEL LEAK. IN THE PRESENCE OF AN IGNITION SOURCE, A FIRE COULD OCCUR.
Remedy:
HONEYWELL WILL NOTIFY OWNERS AND REPLACE THE FUEL FILTERS FREE OF CHARGE. THE RECALL BEGAN ON OCTOBER 18, 2006. OWNERS MAY CONTACT FRAM CUSTOMER SERVICE AT 1-800-890-2075 (OPTION 1).
Potential Units Affected:
88303
Notes:
HONEYWELL INTERNATIONAL, INC.
| Recall Date: |
MAY 16, 1988 |
| Component: |
VEHICLE SPEED CONTROL:ACCELERATOR PEDAL |
| Model Affected: |
BONNEVILLE |
| Potential Units Affected: |
35057
Recall Details
|
Recall Date:
MAY 16, 1988
Model Affected:
1987 PONTIAC BONNEVILLE
Summary:
EXCESSIVE ACCELERATOR CABLE FRICTION MAY RESTRICT THE CABLES FREE MOVEMENT BETWEEN THE ACCELERATOR PEDAL AND THE THROTTLE BODY.
Consequence:
THIS COULD PREVENT THROTTLE FROM RETURNING TO CLOSED(IDLE) POSITION WHEN ACCELERATOR PEDAL IS RELEASED; THUS, ENGINE SPEED WOULDNOT DECREASE, AND LOSS OF ACCELERATOR CONTROL COULD RESULT IN AN ACCIDENT.
Remedy:
REPLACE ACCELERATOR CABLE.
Potential Units Affected:
35057
Notes:
GENERAL MOTORS CORP.